View Personality
Future Light Duke 1200-HMI (FUDUKE.R20)
View Table
; "Future Light Duke 1200-HMI", 8 DMX channels, filename :flduke.r20 ; ; Date By Description ; 19-09-97 S. Anwar Created ; 15-01-98 P.Bari Revised attributes ; 12-03-98 P.Bari Added range tables ; 22-03-05 Phil Rogers Revised device name ; ;---------------------------------------------------------------------------- ; The device name, upto 11 characters, no spaces are allowed DEVICE FU_Duke1200 8 DMX channels NAME "Future Light" "Duke 1200-HMI" ; ;---------------------------------------------------------------------------- ; The Type of instrument, 1 & M must required for backward compatibility ; The middle number denotes the number of DMX channels used TYPE 1 8 M ; ;---------------------------------------------------------------------------- ; Mirror/Head resolution MIRROR 1 150 110 ; | | | ; | | |_______ maximum tilt movement (in degrees) ; | |___________ maximum pan movement (in degrees) ; |_______________ 1 means moving mirror, 2 means moving head ; ;---------------------------------------------------------------------------- ; Patching Information. (Upto 10 lines allowed) ; Upto 10 lines of 159 chars are allowed including formulae ; Variables used d=dmx number(1..512), h=handle(1..60), n=devicename (11-char) ; Allowed modifiers ; +,-,*,/,(,) basic arithmatic ; % means remainder after divide ; & means logical AND ; | means logical OR ; R means reverse the bits of the curernt result (operates on a byte) ; ^ means logical Exclusive OR (operates on a byte) ; > means shift to the right ; < shift to the left ; r followed by number means get the value of that parameter ; d DMX address ; n Fixture name, a 0 terminated character string ; h The handle number DEVICEADDRESS "Handle %2d"h "Fixture %11s"n "DMX %03d"d "" "" "" "" "" "" "" DAEND ; ;---------------------------------------------------------------------------- ; Specify DMX limits ; ; minimum allowed dmx number MINDMX=1 ; ; maximum allowed dmx number MAXDMX=505 ; ; DMX number must be divisible by this DIVBY=1 ; ;---------------------------------------------------------------------------- ; DMX channel description ; ; Column by column description of each DMX channel ; 1. The channels bank number (1..12) ; 2. The upper faders in the bank (1) or the lower faders in the bank (61) ; 3. Channel type (L=LTP, H=HTP, I=Instant LTP, S=16-bit instant LTP, ; s=16-bit Fadeable LTP ; 4. DMX offset (1..number of DMX channels) ; 5. The output level is proportionally recdced by this level (0..100%) ; 6. The curve number (applicable only to HTP channels), usually set to 1 ; 7. Inverted (I) or Normal (N) ; 8. Attribute type (A=Color Wheel1, BCD=Color Mix, E=Pan, F=Tilt, ; G=Iris, H=Dimmer, I=Gobo1, J=Gobo2, K=Gobo1_Rotate, L=Focus, ; M=Gobo2_Rotate, N=Color Wheel2, O=Shutter, P=Prism, Q=Zoom, ; R=Effect_Rotate, S=Frost, 0=uncategorised) ; 9. Checksum channel (Always 1) ;10. Attribute name, must be enclosed in quotes and upto 12 characters allowed ;11. The ON value of this channel (0..255) ;12. The Highlight level of this channel ;13. The Lolight level of this channel ; DMX 3 61 L 1 100 1N E 1 "Pan" 128 -1 -1 3 1 L 2 100 1N F 1 "Tilt" 128 -1 -1 4 1 I 3 100 1N A 1 "Color" 0 0 80 6 1 I 4 100 1N I 1 "Gobo" 0 0 0 6 61 I 5 100 1N K 1 "Gobo-Spin" 0 0 0 2 1 L 6 100 1N G 1 "Iris" 255 255 255 1 1 H 7 100 1N H 1 "Dimmer" 135 135 135 4 61 I 8 100 1N P 1 "Filter" 0 0 0 END ; ;---------------------------------------------------------------------------- ; Text to be displayed when the Instrument is selected for Patching ; TEXT Future Light DUKE 1200 HMI Bank Wheels A B --------------------- 1 Dimmer -- 2 Iris -- 3 Tilt Pan 4 Color Filter 5 -- -- 6 Gobo Gobo-Spin INPUT fixture DMX No. Press a Fixture Select or Swop button to make the patch. END ATTR END ; ;---------------------------------------------------------------------------- ; Tables ; Positions PFTABLE "Positions" -1 1 2 "Middle" 21 80 80 "Left" 22 50 80 "Right" 23 b0 80 "Top" 24 80 50 "Bottom" 25 80 b0 "TLeft" 26 50 50 "TRight" 27 b0 b0 "BLeft" 28 50 b0 "BRight" 29 b0 50 PFEND ; Color table PFTABLE "Colors" -1 3 "White" 1 0 "UV" 2 15 "Cyan" 3 25 "Red" 4 35 "Yellow" 5 45 "Blue" 6 55 "Magenta" 7 65 "Green" 8 75 "C-Spin1" 9 82 "C-Spin2" 10 90 PFEND ; Gobo table PFTABLE "Gobos" -1 4 "Open" 11 0 "Gobo 1" 12 4b "Gobo 2" 13 7d "Gobo 3" 14 af "Gobo 4" 15 e1 PFEND ; Gobo Spin Tables PFTABLE "Gobo-Spin" -1 5 "Static" 11 0 "Static" 16 0 "Spin" 17 2 "Rotate-Clk" 18 80 "Rotate-Anti" 19 c1 PFEND ; Range Tables ; Column by column description... ; 1. Low DMX value (inclusive) ; 2. High DMX value (inclusive) ; 3. Displayed text (max 11 chars) ; Variables used a=low val, b=high val, c=DMX val RANGE 3 ; COLOR 0 15 "White" 16 31 "UltraViolet" 32 47 "Cyan" 48 63 "Red" 64 79 "Yellow" 80 95 "Blue" 96 111 "Magenta" 112 126 "Green" 127 127 "White" 128 255 "Spin %3d%%"(c-a)*100/(b-a) REND RANGE 4 ; GOBO 0 51 "Open" 52 102 "Gobo1" 103 153 "Gobo2" 154 204 "Gobo3" 205 255 "Gobo4" REND RANGE 5 ; GOBO ROT 0 0 "Static" 1 127 "%3d"360*(c-a)*100/(b-a)/100 128 190 ">> %3d%%"(c-a)*100/(b-a) 191 192 "Static" 193 255 "<< %3d%%"(c-a)*100/(b-a) REND RANGE 7 ; DIMMER 0 0 "Shut Closed" 1 129 "Dim %3d%%"(c-a)*100/(b-a) 130 140 "Open" 141 150 "Shut Closed" 151 240 "Strobe %3d%%"(c-a)*100/(b-a) 241 255 "Open" REND RANGE 8 ; FILTER 0 51 "Open" 52 102 "Filt 3200" 103 153 "Filt 6000" 154 204 "Frost Filt" 205 255 "Prism" REND