View Personality
Geni VT-600 (GNVT600.R20)
View Table
; 'Geni VT-600', 11 DMX Channels, filename: GNVT600.R20 ; ; Date By Description ; 25-04-06 Pers Creator Created - Exported from Diamond 4 file. ; 25-04-06 Ed Spencer Checked ; ;---------------------------------------------------------------------------- ; The device name, upto 11 characters, no spaces are allowed DEVICE GN_VT600 mode=11 DMX, 8bit 11 DMX Channels NAME "Geni" "OBY 5U" ; ;---------------------------------------------------------------------------- ; The Type of instrument, 1 & M must required for backward compatibility ; The middle number denotes the number of DMX channels used TYPE 1 11 M ; ;---------------------------------------------------------------------------- ; Mirror/Head resolution MIRROR 0 0 0 ; | | | ; | | |_______ maximum tilt movement (in degrees) ; | |____________ maximum pan movement (in degrees) ; |_________________ 1 means moving mirror, 2 means moving head ; ;---------------------------------------------------------------------------- ; Patching Information. (Upto 10 lines allowed) ; Upto 10 lines of 159 chars are allowed including formulae ; Variables used d=dmx number(1..512), h=handle(1..60), n=devicename (11-char) ; Allowed modifiers ; +,-,*,/,(,) basic arithmatic ; % means remainder after divide ; & means logical AND ; | means logical OR ; R means reverse the bits of the current result (operates on a byte) ; ^ means logical Exclusive OR (operates on a byte) ; > means shift to the right ; < shift to the left ; r followed by number means get the value of that parameter ; d DMX address ; n Fixture name, a 0 terminated character string ; h The handle number DEVICEADDRESS "Handle %2d"h "Fixture %11s"n "DMX %03d"d "" "" "Set to 11 DMX, 8bit" "" "" DAEND ; ;---------------------------------------------------------------------------- ; Specify DMX limits ; ; minimum allowed dmx number MINDMX=1 ; ; maximum allowed dmx number MAXDMX=501 ; ; DMX number must be divisible by this DIVBY=1 ; ;---------------------------------------------------------------------------- ; DMX channel description ; ; Column by column description of each DMX channel ; 1. The channels bank number (1..12) ; 2. The upper faders in the bank (1) or the lower faders in the bank (61) ; 3. Channel type (L=LTP, H=HTP, I=Instant LTP, S=16-bit instant LTP, ; s=16-bit Fadeable LTP ; 4. DMX offset (1..number of DMX channels) ; 5. The output level is proportionally recdced by this level (0..100%) ; 6. The curve number (applicable only to HTP channels), usually set to 1 ; 7. Inverted (I) or Normal (N) ; 8. Attribute type (A=Color Wheel1, BCD=Color Mix, E=Pan, F=Tilt, ; G=Iris, H=Dimmer, I=Gobo1, J=Gobo2, K=Gobo1_Rotate, L=Focus, ; M=Gobo2_Rotate, N=Color Wheel2, O=Shutter, P=Prism, Q=Zoom, ; R=Effect_Rotate, S=Frost, 0=uncategorised) ; 9. Checksum channel (Always 1) ;10. Attribute name, must be enclosed in quotes and upto 12 characters allowed ;11. The ON value of this channel (0..255) ;12. The Highlight level of this channel ;13. The Lowlight level of this channel ; DMX 1 1 H 1 100 1N H 1 "Dimmer" 255 0 0 2 61 L 2 100 1N O 1 "Shutter" 1 0 0 4 1 I 3 100 1N A 1 "Colour 1" 0 0 0 14 61 I 4 100 1N N 1 "Colour 2" 0 0 0 4 61 I 5 100 1N 0 1 "Colour Macro" 0 0 0 3 61 s 6 100 1N E 1 "Pan" 128 0 0 0 0 L 7 100 1N E 1 "Pan Low" 128 0 0 3 1 s 8 100 1N F 1 "Tilt" 128 0 0 0 0 L 9 100 1N F 1 "Tilt Low" 128 0 0 10 1 I 10 100 1N 0 1 "Control" 0 0 0 10 61 I 11 100 1N 0 1 "Lamp Switch" 0 0 0 END ; ;---------------------------------------------------------------------------- TEXT Geni VT-600 11 DMX, 8bit INPUT fixture DMX No. Press a Fixture Select or Swop button to make the patch. END ATTR Function Obsolete END ;---------------------------------------------------------------------------- ; Preset Palette Tables ;---------------------------------------------------------------------------- ; Macros MACRO "Lamp On" 1 10 11 "data" 0 0 48 "delay" 1 28 "data" 0 4 48 "delay" 1 A MEND MACRO "Lamp Off" 2 11 "data" 0 48 "delay" 1 28 "data" 0 18 "delay" 1 A MEND MACRO "Reset" 3 10 "data" 0 E0 "delay" 1 28 "data" 0 4 "delay" 1 A MEND ;---------------------------------------------------------------------------- ; Range Tables ; Column by column description... ; 1. Low DMX value (inclusive) ; 2. High DMX value (inclusive) ; 3. Displayed text (max 11 chars) ; Variables used a=low val, b=high val, c=DMX val RANGE 2 ;Shutter 0 0 "Closed" 1 7 "Open" 8 63 "Strobe %3d%%"0+(((c-a)*100)/(b-a)) 64 71 "Open" 72 127 "Open P %3d%%"0+(((c-a)*100)/(b-a)) 128 135 "Open" 136 191 "Close %3d%%"0+(((c-a)*100)/(b-a)) 192 199 "Open" 200 253 "Rnd St %3d%%"0+(((c-a)*100)/(b-a)) 254 255 "Open" REND RANGE 5 ;Colour Macro 0 7 "Safe" 8 15 "Macro 1" 16 23 "Macro 2" 24 31 "Macro 3" 32 39 "Macro 4" 40 47 "Macro 5" 48 55 "Macro 6" 56 63 "Macro 7" 64 71 "Macro 8" 72 79 "Macro 9" 80 87 "Macro 10" 88 95 "Macro 11" 96 103 "Macro 12" 104 111 "Macro 13" 112 119 "Macro 14" 120 127 "Macro 15" 128 135 "Macro 16" 136 143 "Macro 17" 144 151 "Macro 18" 152 159 "Macro 19" 160 167 "Macro 20" 168 175 "Macro 21" 176 183 "Macro 22" 184 191 "Macro 23" 192 199 "Macro 24" 200 207 "Macro 25" 208 215 "Macro 26" 216 223 "Macro 27" 224 231 "Macro 28" 232 239 "Macro 29" 240 247 "Macro 30" 248 255 "Macro 31" REND RANGE 10 ;Control 0 7 "P/T Auto" 8 63 "P/T Manual" 64 127 "Cols Adjust" 128 191 "Save Offset" 192 255 "Reset" REND RANGE 11 ;Lamp Switch 0 47 "Safe" 48 95 "Lamp On" 96 159 "Safe" 160 207 "Lamp Off" 208 255 "Safe" REND